The activating enhancer binding protein 2 (AP2) family of transcr

The activating enhancer binding protein 2 (AP2) family of transcription factors is expressed during mammalian development and in certain malignant diseases. This article summarizes the data regarding expression and function of murine Tcfap2 and human TFAP2 in extraembryonic development and differentiation. It also presents a model integrating Tcfap2c into the framework of trophoblast development and highlights the requirement of

Tcfap2c to maintain trophoblast stem cells. With regard to human trophoblast cell-lineage Linsitinib mw restriction, the role of TFAP2C in lineage specification and maintenance is speculated upon. Furthermore, an overview of target genes of AP2 in mouse and human affecting placenta development and function is provided and the evidence suggesting that defects in regulating TFAP2 members might contribute to placental defects is discussed. (C) 2012, Reproductive Healthcare Ltd. Published by

Elsevier Ltd. All rights reserved.”
“Background: Knowledge CDK inhibitor of in vivo glenohumeral joint contact mechanics after total shoulder arthroplasty may provide insight for the improvement of patient function, implant longevity, and surgical technique. The objective of this study was to determine the in vivo glenohumeral joint contact locations in patients after total shoulder arthroplasty. We hypothesized that the glenohumeral joint articular contact would be centered on the glenoid surface because of the ball-in-socket geometric features

of the implants.

Methods: Dual-plane fluoroscopic images and computer-aided design models were used to quantify patient-specific glenohumeral articular contact in thirteen shoulders following total shoulder arthroplasty. The reconstructed shoulder was imaged at arm positions of 0 degrees, 45 degrees, and 90 degrees of abduction (in the coronal plane) and neutral rotation and at 90 degrees of abduction with maximum internal and external rotation. The patients were individually investigated, and their glenohumeral joint contact centroids were STA-9090 in vitro reported with use of contact frequency.

Results: In all positions, the glenohumeral joint contact centroids were not found at the center of the glenoid surface but at an average distance (and standard deviation) of 11.0 +/- 4.3 mm from the glenoid center. Forty (62%) of the sixty-five total contact occurrences were found on the superior-posterior quadrant of the glenoid surface. The position of 0 degrees of abduction in neutral rotation exhibited the greatest variation of quadrant contact location; however, no contact was found on the superior-anterior quadrant of the glenoid surface in this position.

Conclusions: In vivo, glenohumeral joint contact after total shoulder arthroplasty is not centered on the glenoid surface, suggesting that kinematics after shoulder arthroplasty may not be governed by ball-in-socket mechanics as traditionally thought.

Comments are closed.