Similarly, the first vowels of the initially stressed targets (me

Similarly, the first vowels of the initially stressed targets (mean length 142 ms) were longer than the first vowels of the initially unstressed targets (63 ms), t(47) = 12.42, p < .001. Maximum pitch and maximum intensity was reached earlier for stressed target word onset syllables (initially stressed targets) than for the unstressed target word onset syllables (initially unstressed targets), both t(47) = 3.35, p ⩽ .002. In addition, initially stressed and unstressed syllables also differed in mean intensity, which was higher for stressed compared to unstressed word onset syllables, t(47) = 3.37, p = .002. Driven by the second syllables, initially stressed target words (mean duration 479 ms) were CP-868596 research buy shorter than initially unstressed

target words (520 ms), t(47) = 4.23, p < .001. Each participant heard 768 trials (384 target words, 384 target pseudowords). The experiment consisted of four blocks. In each block 192 trials were presented. All 96 words, that is 48 initially stressed words and 48 initially unstressed words, and all 96

pseudowords, that is 48 initially stressed pseudowords and 48 initially unstressed pseudowords, were combined with a prime in one of the eight conditions respectively (see Table 1B). Within and across blocks, the order of trials was randomized. Block order was permuted across participants following Latin square logic. Participants were comfortably seated in an Autophagy inhibitor electrically shielded and sound attenuated room. An experimental trial started with the presentation of a white fixation cross (font size: 25) at the center of a computer screen in front of the participants (distance: 70 cm). Participants were instructed to fixate this cross whenever it appeared. A syllable prime was presented

via loudspeakers 500 ms after the onset of the Histone demethylase fixation cross. The target was delivered 250 ms after offset of the prime. Half of the participants were instructed to press the left mouse button to words and the right mouse button to pseudowords (reversed response mapping for remaining participants). Participants were asked to respond as quickly and as accurately as possible. After pressing the mouse button the next trial started with a delay of 1500 ms. If no response occurred the next trial started after a 3500 ms delay. The fixation picture remained on the screen until a response button was pressed or until the critical time window of 3500 ms was over. The loudspeakers were placed at the left side and the right side of the screen. Auditory stimuli were presented at approximately 70 db. The continuous EEG was recorded at a 500 Hz sampling rate (bandpass filter 0.01–100 Hz, BrainAmp Standard, Brain Products, Gilching, Germany) from 74 nose-referenced active Ag/AgCl electrodes (Brain Products) mounted in an elastic cap (Electro Cap International, Inc.) according to the international 10–20 system (two additional electrodes were placed below the eyes, ground electrode was placed at the right cheek).

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>